NOS now available CALL US. NOT AVAILABLE TO ORDER ONLINE
PowerAIM 120 Vector Impedance Analyzer for Broadcast Engineers. Manufactured by Array Solutions
The PowerAIM 120 Vector Impedance Analyzer with patented, unique technology offers the broadcast engineer the full capabilities of a single port network analyzer in a small, lightweight, software-driven instrument that is easy to carry on airlines and in the field. It is very simple to set up and use. The Power AIM 120 is accurate even at tens of thousands of ohms of impedance. All impedance parameters are measured and calculated. The software for the PowerAIM is loaded on a laptop computer, which is coupled to the instrument via a RS-232 cable or using a standard USB to RS-232 adapter. The PowerAIM is particularly beneficial to broadcast engineers involved in the adjustment and final commissioning of AM HD
- High resolution plots of all selected parameters, including R, X, SWR, reflection coefficient, return loss, load impedance magnitude, and load impedance phase angle.
- VSWR sideband ratio tool which will quickly calculate the sideband VSWR ratios and IBOC requirements.
- Fast and Accurate measurements allow for quick tune-ups and documentation via real-time PC data plotting over large ranges of frequency and impedance.
- Variable scaling of the frequency range and the parameter magnitude limits for clear data collection and read-outs both during a test session and afterwards in off-line analysis.
- Fast sweeps and easy multiple plot and data point measurement saving for self-documentation and export to Microsoft Excel for further plotting and analysis.
- Data curve averaging, trending and smoothing capabilities are available to reduce test measurement noise on the measurements
- Co-station and strong adjacent channel interference DSP tools can be used to read antenna data perfectly.
- Scan overlay feature for rapid detection of system changes and the affects of adjustments.
- Recycle mode for continuous scan updates during adjustments.
- PC/Windows-based software, including frequency plots, calibration tools, transmission-line tools, and Smith charts, for rapid, easy field and laboratory based integrated antenna and component system calculations.
- We DO NOT ship a software CDROM with the analyzer.
- Software updates via the Internet to assure long instrument lifetime of all features.
- Very light weight and portable, the waterproof carrying case can hold the PowerAim 120, battery, battery charger, and your
- PC. Very portable and reliable and replaces much heavier equipment.
- Easy to calibrate with the included loads or your own NIST traceable loads. The test frequency can also be calibrated with a counter or a receiver tuned to WWV. All calibration is done without screwdriver adjustments. Any Calibration lab can certify this instrument.
- Frequency plots, Smith charts, Smith chart rotation, transmission line tools, markers, and many software based functions to help make your measurements and calculations fast, easy, and accurate.
- Measures and displays equivalent series resistance and reactance, as well as the equivalent parallel resistance and reactance. Reactance is also shown as inductance (uH) or capacitance (pF) according to the phase angle. Allowing quick and accurate adjustments.
- Auditory tone output makes manual adjustments easy and fast without watching the monitor.
- Signal source mode allows the PowerAim 120 to be used as a signal generator.
- Strong-signal immunity built into the design with patent-pending filter technology to assure accurate measurements, even in the presence of nearby strong signals.
- The PowerAIM 120 Software can calibrate out to the ends transmission lines, and special purpose fixtures you have designed to measure components.
- The PowerAIM 120 includes a transmission line tool that will translate the impedance to the end of a transmission line that you specify.
- Simultaneous rectangular and Smith chart plots, with automatic tracking, mouse-directed cursor to specific frequencies, and up to 20 user-specified marker frequencies.
- Frequency spectrum scan mode to identify nearby stations and their relative intensity.
- Transmission line length measurements and velocity factor calculations.
- Input protections, including RF voltage measurement, measurement system isolation, and EMP/static protection, for rugged reliable service.
PowerAIM Specifications
- Frequency Control: Digital Synthesizer 0.1 - 120 MHz; Stability: +/- 30 ppm
- Frequency Step Size: from 1 Hz to 10 MHz
- Calibration: software controlled (no screwdriver adjustments). Easy to calibrate to NIST standards.
- Analog to digital converter resolution: 12 bits. Data averaging up to 256X.
- Measurement Ranges: SWR: 1:1 to 20:1 and up to 100:1 with reduced accuracy.
- Impedance: 1 Ω to 5 kΩ and up to 20 kΩ with reduced accuracy.
- Impedance Accuracy: 1 Ω +/- 3% of reading up to 60 MHz, 5% of reading up to 120 MHz
- Phase Angle: +/-90 degrees (true phase)
- Parameters displayed include: SWR, Reflection coefficient, Return loss, Magnitude of load impedance, Phase angle of load impedance, Equivalent series resistance and reactance, Equivalent parallel resistance and reactance. Reactance is shown as inductance (uH) or capacitance (pF) according to the phase angle.
- Two Smith Chart displays, one with a specifiable phase delay.
- Data can be referenced to the antenna terminals.
- RF connector: N-type
- Spurious output: 30 dBc or better
- Max stray RF input while measuring: 25 V peak, 50 V p-p
- Max safe RF input: 50 V peak, 100 V p-p
- PC Interface: RS232 (USB adapter optional). Data rate = 57.6 kbaud or 115 kbaud
- Display: Graphics output on PC. A 1024 x 768 or larger screen is recommended, although 640 x 480 can be used. Mouse controlled cursor for digital parametric readout. Audible tone for SWR indication. Morse code output for selected parameters.
- Power Supply: 11 to 16 V DC at 500 mA (12V 5 Ah Sealed battery and universal charger included)
- Required current is approximately 500 mA when a measurement is in process, 100 mA when idle. Auto-power-off after 10 minutes of inactivity.
- PowerAim 120 Dimensions (approx): 5" x 4" x 2" (12.7 cm x 10.2 cm x 5.1 cm)
- Dimension Pelican case Exterior Dimensions: 21.6" L x 17.2" W x 4.9" D (55 cm x 43.7 cm x 12.5 cm) lockable, sealed, watertight
- Software for the analyzer hardware controller and the PC data analysis is upgradeable in the field. 1 year free software updates.
- We DO NOT ship a software CDROM with the analyzer.
- Warranty 2 Years limited warranty (see complete details in manual)
- Note - CIRCUITS AND PROCEDURES used by this antenna analysis system are covered by US Patent No. 7,629,795
- Polar plots of SWR, Z and S11 can be displayed.
- Band skipping greatly speeds up analysis of multiband antennas.
- Audible output for SWR reading. Listen to the AIM at a remote location.
- SWR can be plotted on log scales. Greater dynamic range for SWR display.
- Plot Point Data on Smith chart while tuning or adjusting freq.
- Option to start graph at freq=0.
- Click on .scn file to launch program and display the .scn file.
- Show date and time on Smith chart.
- Option to load and overlay graphs. (Start/End freqs must be the same.)
- Custom cal start freq can be as low as 100 kHz.
- Graph legend is in a separate window that can be repositioned.
- Plot Q vs. Frequency.
- Display Q in data window on right side.
- Menu item (under 'Help') to check for program update.
- The PowerAIM Supplement and the AIM manual have been updated.
- PowerAIM Specifications
- Frequency Control: Digital Synthesizer 0.1 - 120 MHz; Stability: +/- 30 ppm
- Frequency Step Size: from 1 Hz to 10 MHz
- Calibration: software controlled (no screwdriver adjustments). Easy to calibrate to NIST standards.
- Analog to digital converter resolution: 12 bits. Data averaging up to 256X.
- Measurement Ranges:
- SWR: 1:1 to 20:1 and up to 100:1 with reduced accuracy.
- Impedance: 1 Ω to 5 kΩ and up to 20 kΩ with reduced accuracy.
- Impedance Accuracy: 1 ohm +/- 3% of reading up to 60 MHz, 5% of reading up to 120 MHz
- Phase Angle: +/-90 degrees (true phase)
- Parameters displayed include: SWR, Reflection coefficient, Return loss, Magnitude of load impedance, Phase angle of load impedance, Equivalent series resistance and reactance, Equivalent parallel resistance and reactance. Reactance is shown as inductance (uH) or capacitance (pF) according to the phase angle.
- Two Smith Chart displays, one with a specifiable phase delay
- Data can be referenced to the antenna terminals.
- RF Output: Type-N connector
- Spurious output: 30dBc or better
- Max stray RF input while measuring: 25 V peak, 50 V p-p
- Max safe RF input: 50 V peak, 100 V p-p
- PC Interface: RS232 (USB adapter optional). Data rate = 57.6 kbaud or 115 kbaud
- Display: Graphics output on PC. A 1024 x 768 or larger screen is recommended, although 640 x 480 can be used. Mouse controlled cursor for digital parametric readout. Audible tone for SWR indication. Morse code output for selected parameters.
- Power Supply: 11 to 16 V DC at 500 mA (12V 5 Ah Sealed battery and universal charger included)
- Required current is approximately 500 mA when a measurement is in process, 100 mA when idle. Auto-power-off after 10 minutes of inactivity.
- PowerAim 120 Dimensions (approx): 5" x 4" x 2" (12.7 cm x 10.2 cm x 5.1 cm)
- Dimension Pelican case Exterior Dimensions: 21.6" L x 17.2" W x 4.9" D (55 cm x 43.7 cm x 12.5 cm) lockable, sealed, watertight
- Software for the analyzer hardware controller and the PC data analysis is upgradeable in the field. One year free software updates.
- Warranty 2 Years limited warranty (see complete details in manual)
Power AIM-120 - Power AIM 120 professional broadcast antenna analyzer kit
- Brand: Array Solutions
- Product Code: PowerAIM-120
- Availability: In Stock
-
$0.01
Related Products
Tags: antenna analyser, impedance network analyser, antenna analyzer, aim, bradcast analyser, impedance network analyzer, network analyser, aim4300, power analyzer, aim-4300, aim120, broadcast analyzer, network analyzer, power aim120, power aim, aim-120, power aim-120, power aim 120, PowerAIM-120, power master